· Accuracy: +/- 1.0dB (125Hz ~ 4Khz) · Resolution: 0.1dB · Frequency: 31.5Hz to 8Khz) · Display: Large 0.7” (2000 count) LCD · A & C Frequency Weighting · Sound Meter Range: 30dB to 130dB (3 Ranges) · Meets IEC 651 Type 1 Standards
Specifications
Display 18mm (0.7") LCD, 3 1/2 Digits Function dB (A & C frequency weighting), Time weighting (Fast, Slow), Max. hold, Max. hold reset, AC output Measurement Range 3 Ranges, (30dB ~ 70dB, 60dB ~ 100dB, 90dB ~ 130dB) Resolution 0.1 db Accuracy (23 ± 5°C) Time weighting & frequency weighting meet IEC 651 type 1, calibrating input signal on 94 dB(31.5 Hz to 8 kHz), then the accuracy of A weighting is specified as following:. 31.5Hz ~ ± 1.5dB, 63Hz ~ ± 1.5dB, 125Hz ~ ± 1dB, 250Hz ~ ± 1dB, 500Hz ~ ± 1dB, 1kHz ~ ± 1dB, 2kHz ~ ± 1dB, 4kHz ~ ± 1dB, 8kHz ~ ± 2dB to -3dB Frequency Weighting Network Characteristics of A & C. A weighting - The characteristic is simulated as "Human Ear Listening" response. Typical, if making the environmental sound level management, always select to A weighting. C weighting - The characteristic is near the "FLAT" response. Typical, it is suitable for checking the noise of machinery (Q.C. check) & knowing the sound pressure level of the tested equipment. Frequency 31.5 Hz ~ 8,000 Hz Calibrator B & K (Bruel & Kjaer), multi-function acoustic calibrator, model: 4226 Microphone Electric condenser microphone Size of Microphone 0.5" standard size Range Selector 30 to 70dB, 60 to 100dB, 90 to 130dB, 40dB on each step, with over & under range indicating. Time Weighting (Fast & Slow) Fast - t=200ms, Slow - t=500ms *Fast range is simulated the human ear response time weighting. *Slow range is easy to get the average values of vibration sound level. *The "Fast" & "Slow" time weighting range are designed to IEC 651 type 2 requirement. Output Signal AC output - AC 0.4 Vrms corresponding to each range step. Calibration Build in external calibration. VR, easy to calibrate on 94 dB level by screw driver. Internal oscillation system, 1 KHz sine wave generator. Out Terminal 3.5mm dia. phone output terminal is provided for connection with analyzer, level recorder, tape recorder. Operating Temperature 0°C ~ 50°C (32°F to 122°F) Operating Humidity Max. 90% RH (0°C ~ 35°C) Power Supply DC 9V battery x 2 PCs, 006P, MN1604 (PP3) or equivalent, heavy duty or alkaline type. Power Consumption Approx. DC 17mA Dimension 260 x 87 x 36mm (10.2 x 3.4 x 1.4 inch) Weight 450g/0.99 LB Standard Accessories Instruction Manual, Carrying case Optional Accessories 94dB Sound Calibrator, Model: SC-940, model: SC-941
|